> Ready to upgrade your HVAC or hydronic system? Get a free consultation and quote
> for your custom project in BC—let’s bring efficiency and innovation to your space!

 [ Contact us ](http://qg1.ec2.mytemp.website/contact-us)

Welcome to the Projects Gallery at Zencore Dynamics. This section features a selection
of our completed work in Controls, HVAC, and Hydronics, including photos and key
details for each project. Explore examples of our installations and systems designed
to meet the requirements of various applications in British Columbia.

## Precision Hydronics: Air-to-Water & Boiler Mastery

 [  Monobloc In-Floor Radiant & Chilled Fan Coils Retrofit | Bowen Island, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-monobloc-in-floor-radiant-&-chilled-fan-coils-retrofit-|-bowen-island,-bc)

In this comprehensive retrofit on Bowen Island, we addressed a severely compromised
Daikin Altherma monobloc system that had failed to deliver reliable heating or cooling.
The original setup relied on a domestic pre-heat hot water tank backed by an electric
boiler for hydronics and a propane boiler for domestic hot water. Issues included
non-functional cooling, erratic heating that activated all fans simultaneously, 
uneven performance across zones, and severe bacterial buildup and sludge in the 
tank due to unmanaged hysteresis—revealed during demolition.

Our solution centered on an efficient IBC HPX 5 monobloc heat pump paired with an
Altsource buffer tank for stable operation. We integrated an IBC Superflow combination
boiler as a dedicated radiant backup, while routing domestic hot water directly 
through the IBC without pre-heating to streamline flow. To enhance zoning, we replaced
the single oversized pump with multiple smaller zone pumps, improving distribution
and energy use.

Controls were simplified from custom PLC logic to a reliable Tekmar 404 house manager,
pump controller, and 557 thermostats, enabling precise mixed-zone management for
both heating and cooling. This upgrade restored full functionality, eliminated maintenance
pitfalls, and optimized efficiency for the island’s variable climate.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20241028_145928-400x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20241028_142818-400x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20241028_144611-400x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20241230_152605-225x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20241028_141310-400x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20241028_141315-400x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20241126_152321-800x370.
jpg)

![IBC Air-to-Water Heat Pump Retrofit installation on Bowen Island BC, featuring
IBC Superflow 99 combination boiler, buffer tank, piping, valves, and controls for
efficient heating and cooling system.](https://zencoredynamics.ca/wp-content/uploads/
2025/10/20241213_170718-710x400.jpg)

IBC Superflow 99 Air-to-Water Retrofit and Buffer Tank Setup for Heating & Cooling

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20241226_184312-710x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250109_151154-225x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250220_175137-225x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250224_160527-225x400.
jpg)

 [  IBC Monoblock Retrofit | Bowen Island, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-ibc-monoblock-retrofit-|-bowen-island,-bc)

For this straightforward retrofit in a 5-unit housing development on Bowen Island,
we tackled a malfunctioning Daikin 5-ton monobloc air-to-water heat pump that had
ceased delivering consistent hydronic heating. The unit’s integrated circulation
was inadequate for the multi-unit demands, leading to pressure imbalances and unreliable
performance across the shared system.

Our targeted intervention involved installing a dedicated external circulation pump
to ensure robust flow distribution and a pressure relief valve to safeguard against
over-pressurization events. This minimalistic upgrade restored optimal operation
without major system overhauls, enhancing reliability and efficiency for the community’s
radiant heating needs in the island’s temperate coastal environment.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250828_143738-185x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250829_164748-1-185x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250830_140132-185x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250830_140124-185x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250830_141132-1-185x400.
jpg)

 [  IBC Boiler Retrofit | Anmore, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-ibc-boiler-retrofit-|-anmore,-bc)

In this upgrade nestled in the scenic community of Anmore, we decommissioned an 
aging atmospheric boiler paired with an indirect domestic hot water tank—a notoriously
leaky iron relic that suffered from chronic corrosion, inefficient combustion, and
escalating energy costs. The system’s outdated design led to frequent leaks, poor
thermal efficiency, and unreliable hot water delivery, compromising comfort in the
home’s hydronic setup.

We replaced it with a compact, high-efficiency IBC Superflow combination boiler,
seamlessly integrating domestic hot water production without the need for a separate
tank. This modern unit delivers precise on-demand heating and hot water, slashing
energy use by up to 30% while eliminating leak risks and simplifying maintenance.
Tailored for Anmore’s mild yet variable climate, the installation enhances reliability
and sustainability for year-round performance.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20230125_092618-187x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20230125_092621-187x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20230125_092614-187x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240925_120530-533x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20241010_162014-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20241012_151709-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250103_173559-225x400.
jpg)

 [  Rinnai Combi Boiler | Vancouver, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-rinnai-combi-boiler-|-vancouver,-bc)

During a thoughtful home renovation in Vancouver’s vibrant East End, we integrated
a Rinnai 99i high-efficiency combination boiler to modernize hydronic heating for
longstanding cast iron radiators while providing instantaneous domestic hot water.
The original setup struggled with inconsistent temperatures from the aging radiators’
high thermal mass and sluggish response times, compounded by an inefficient separate
water heater that couldn’t keep pace with on-demand needs in the bustling urban 
household.

The Rinnai 99i delivers compact, wall-mounted performance with modulating output
for precise control, ensuring even heat distribution across the radiators without
short-cycling and instant hot water at the taps to eliminate wait times. This seamless
upgrade preserves the home’s historic charm while boosting energy efficiency by 
over 25%, reducing operational costs, and aligning with Vancouver’s progressive 
building standards for sustainable retrofits.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231101_105834-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231106_091340-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231106_101238-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231106_101245-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231114_124758-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231114_124923-300x400.
jpg)

 [  Rinnai Combi Boiler Retrofit | Langley, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-rinnai-combi-boiler-retrofit-|-langley,-bc)

In a targeted retrofit for a Langley residence, we resolved persistent heating inconsistencies
where certain areas remained underheated despite full system operation. The culprit
was an original EcoKing boiler, poorly installed and vibrating loose from its wall
mount, compounded by operation at a maximum 180°F water temperature without a primary
loop or proper boiler separation—leading to inefficient circulation, short-cycling,
and uneven distribution across the hydronic zones.

We replaced it with a reliable Rinnai combination boiler, incorporating a dedicated
primary loop and hydraulic separation for balanced flow and protection against thermal
stress. This upgrade included secure mounting to eliminate vibrations and precise
temperature modulation for optimal performance. The result: uniform heating throughout
the home, enhanced energy efficiency, and reduced maintenance demands suited to 
Langley’s fluctuating seasonal demands.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240924_101821-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240924_104357-300x400.
jpg)

# Integrated Controls: PLCs & LED Lighting

 [  Custom Geothermal Controls Integration | West Vancouver, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-custom-geothermal-controls-integration-|-west-vancouver,-bc)

Called in at the eleventh hour during drywall installation for a sprawling West 
Vancouver estate, we engineered a bespoke controls solution for an intricate geothermal
system featuring a custom-imported chiller serving 13 hydronic fan coils. The setup
included dual buffer tanks—one hydronic, one geothermal—demanding tailored relays,
pump timers, and freeze protection to manage complex flows and prevent operational
hiccups.

Domestic hot water was prioritized via a heat pump tank, with seamless failover 
to a Rinnai combination boiler that doubled as geothermal backup, orchestrated through
a modulating valve for on-demand switching between tank storage and boiler production.
At the core, we deployed a Tekmar 404 house controller, augmented by multiple zone
controllers, mixing valves, and wireless outdoor sensors for intelligent, adaptive
performance. To complete the smart-home ecosystem, we integrated energy-efficient
LED lighting, security cameras, and full-home Ethernet networking, transforming 
potential chaos into a harmonious, reliable system tailored for coastal luxury living.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240313_093736-187x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231113_082249-533x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231113_083321-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231113_083326-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231212_114845-533x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231228_094837-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20231228_141345-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240125_140300-187x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240125_140309-187x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240208_113446-187x400.
jpg)

![Tekmar zone controls and house controller panel for geothermal hydronic system
in Vancouver BC, with wiring, relays, and modules for fan coils and heating.](https://
zencoredynamics.ca/wp-content/uploads/2025/10/20240308_115521-scaled-e1762818621156-
303x400.jpg)

Tekmar Control Panel for Geothermal Hydronic System

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240320_120511-187x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240320_120525-800x374.
jpg)

 [  Custom Dot-Free LED Lighting Installation | Port Moody, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-custom-dot-free-led-lighting-installation-|-port-moody,-bc)

For Oxygen Yoga and Fitness in Port Moody, we crafted a mesmerizing, dot-free LED
lighting ambiance that elevates the studio’s serene yet invigorating atmosphere.
This labor-intensive yet rewarding endeavor involved meticulously wrapping the studio
perimeter with 45°-angled diffuser channels to diffuse a vibrant spectrum of colors,
creating an immersive rainbow glow without visible hotspots. We strategically placed
four infrared panels in the corners and beneath the expansive studio mirror to enhance
warmth and visual depth.

The system features 15 independently programmable zones, all seamlessly wired to
a central decoder and transformer panel, allowing effortless customization of any
hue, intensity, or dynamic lighting sequence via intuitive controls. Sourced from
BL Lighting in Vancouver, this installation not only supports the studio’s wellness-
focused vibe but also ensures low-maintenance, energy-efficient operation tailored
to Port Moody’s dynamic community of yogis.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/DSC_0305-599x400.png)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/DSC_0278-599x400.png)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/DSC_0282-267x400.png)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/DSC_0296-599x400.png)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250909_155857-800x370.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250826_153655-800x370.
jpg)

 [  Mitsubishi Ducted Heat Pump Controls Solution | Bowen Island, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-mitsubishi-ducted-heat-pump-controls-solution-|-bowen-island,-bc)

For this custom home on Bowen Island, we implemented a tailored controls system 
for two Mitsubishi ducted 5-ton heat pumps and fan coils. One unit handles zoning
for the top floor and basement, while the second serves the main floor, ensuring
balanced climate management across levels.

We deployed three Tekmar 086 mud sensors to average temperatures in each zone, paired
with three Tekmar 557 thermostats centralized in the mechanical room. These connect
via a Tekmar Gateway, enabling seamless integration with the home’s automation platform
for remote monitoring and adjustments.

Additionally, a dedicated Tekmar 557 thermostat activates electric floor heating
in the breezeway, using remote temperature and humidity sensors. Elevated humidity
levels automatically engage an inline fan to promote air circulation and ventilation,
enhancing indoor air quality in this transitional space. This setup delivers precise,
efficient control suited to the island’s coastal conditions.

 [  Ambient White LED Lighting Installation | West Vancouver, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-ambient-white-led-lighting-installation-|-west-vancouver,-bc)

In this elegant home in West Vancouver, we enhanced the interior ambiance with seamless
ambient white LED lighting, installing several hundred feet of high-quality strip
lights into recessed features throughout key spaces. The setup illuminates the living
room and kitchen for a warm, inviting glow during gatherings, extends to the upper
hallway for safe and subtle navigation, and adds a spa-like serenity to the master
bedroom and bathroom. This energy-efficient solution provides customizable brightness
levels, long-lasting performance, and minimal heat output, perfectly complementing
the home’s modern design while reducing electricity costs in the coastal setting.

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20251028_140806-185x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20251028_132909-185x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20251028_132916-800x370.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20251028_132945-185x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20251028_132957-185x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20251028_140402-800x370.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20251028_140421-185x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20251028_140452-800x370.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20251028_140500-800x370.
jpg)

# HVAC: Heating, Ventilation and A&C Systems

 [  Daikin Fit HVAC Retrofit | Belcarra, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-daikin-fit-hvac-retrofit-|-belcarra,-bc)

Perched along Belcarra’s stunning coastline, this glass-filled home had undergone
multiple renovations, resulting in a fragmented Trane centralized HVAC system that
delivered uneven heating and struggled to meet demands, leaving occupants uncomfortable
in varying zones.

We dismantled the outdated setup and introduced a Daikin Fit system, dividing the
home into two efficient zones: a 2-ton medium static fan coil—carefully disassembled
into sections for access into the confined attic space before reassembly—with fresh
ductwork for precise upper-level control, and a 3-ton coil atop a Daikin 90k BTU
furnace serving the lower three floors. Both zones draw from a robust 5-ton heat
pump for optimal performance.

To ensure redundancy, we incorporated a manual damper that, when opened during heat
pump malfunctions, channels gas furnace heat to the top floor, maintaining consistent
comfort and reliability amid the coastal microclimate.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20230112_134743-800x374.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20230112_141257-800x374.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20230412_133910-187x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20230607_135721-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20230623_132443-533x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20230629_141746-533x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20230629_141755-533x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240910_130246-533x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240910_130117-533x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240910_130125-533x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240910_130450-533x400.
jpg)

 [  Samsung Hylex Heat Pump Retrofit | Burnaby, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-samsung-hylex-heat-pump-retrofit-|-burnaby,-bc)

For a valued long-time client whose system failed during a harsh cold snap in late
2024, we performed a rapid retrofit by replacing the outdated York 5-ton heat pump
with a high-efficiency Samsung Hylex unit. Keeping the existing indoor coil in the
attic simplified the installation, making it a straightforward upgrade—aside from
the challenging hours chiseling through thick ice that had bonded the old unit to
its curb. Now mounted on a sturdy stand, this inverter-driven system with customized
controls not only slashes energy consumption and reduces reliance on the attic’s
electric resistive heater but also operates remarkably quieter than the original,
minimizing noise disruption for a more peaceful home environment well-suited to 
British Columbia’s variable winters.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250111_083232-1-225x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250111_084204-1-225x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250111_102943-1-225x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250111_173436-1-225x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250112_104835-1-225x400.
jpg)

 [  Samsung Ducted Fan Coils & HRV Installation | Langford, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-samsung-ducted-fan-coils-&-hrv-installation-|-langford,-bc)

In this expansive 27-unit housing development comprising six three-story buildings
in Langford, we delivered a comprehensive HVAC solution tailored for multi-family
efficiency. Each unit features Samsung ducted fan coils discreetly installed in 
drop ceilings: a dedicated coil for the bottom floor, a 12,000 BTU model serving
the main floor, and dual 9,000 BTU units on the top floor to independently condition
the primary and secondary bedrooms, ensuring zoned comfort and minimal noise intrusion.

Complementing the system, we integrated FanTech HRVs with bathroom timers to promote
fresh air exchange, humidity control, and energy recovery—vital for maintaining 
indoor air quality in the humid coastal climate. This scalable installation optimizes
energy use, supports sustainable building practices, and enhances resident comfort
across the development’s diverse layouts.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20250414_100125-800x370.
jpg)

![Samsung Multi Zone Heat Pump installed on rooftop in Langford BC project, with
refrigeration gauges attached for system testing.](https://zencoredynamics.ca/wp-
content/uploads/2025/10/20250514_083428-800x370.jpg)

Samsung Multi Zone Heat Pump on Langford Rooftop with Refrigeration Gauges

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/20240905_144745-533x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/IMG_20240906_115455_203-
533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/SiteCam_1718811649153-
533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/SiteCam_1725466110905-
533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/SiteCam_1720557737699-
300x400.jpg)

# The Art Of Fire: Gas Lines, BBQs and Fire Bowls

 [  Gas Line & Firebowl Installation | Anmore, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-gas-line-&-firebowl-installation-|-anmore,-bc)

As part of an upscale patio renovation in picturesque Anmore, we installed a 50-
foot gas line to power a custom firebowl, transforming the outdoor space into a 
cozy gathering spot. The line was trenched and buried to code-compliant depths using
durable corrugated stainless steel tubing for safe, efficient propane delivery, 
ensuring reliable ignition and flame control without visible disruptions to the 
landscaped area. The integrated firebowl features adjustable heat output and weather-
resistant construction, enhancing ambiance and extending usability through cooler
evenings while adhering to local safety standards for gas appliances in residential
settings.

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/Screenshot-2025-11-05-
135305-378x400.png)

 [  Pizza Oven & Firepit Installation | Vancouver, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-pizza-oven-&-firepit-installation-|-vancouver,-bc)

In this outdoor enhancement project, we ran a dedicated gas line to power a high-
performance outdoor pizza oven while upgrading a Paloform Bolo fire pit with a new
electronic ignition burner. The Bolo, a 42-inch diameter modern fire bowl crafted
from weathering Corten steel, now features seamless electronic ignition—activated
simply by turning on the power supply for automatic pilot and main burner lighting,
with safety features to prevent gas leaks. Compatible with natural gas or propane,
this installation ensures efficient, reliable flame control and easy operation, 
elevating backyard gatherings with minimal maintenance and enhanced safety standards.

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20240612_090903-187x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20240605_132736-800x374.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20240612_090856-187x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20240605_132822-1-800x374.
jpg)

# Mechanical Designs: Hydronics, HVAC and Controls

 [  Radiant and HRV Mechanical Design | Vancouver, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-radiant-and-hrv-mechanical-design-|-vancouver,-bc)

For this residential project in Vancouver, we designed a simple radiant baseboard
heating system integrated with an HRV for balanced ventilation, ensuring even warmth
and fresh air circulation throughout the home. To meet municipal standards, we prepared
detailed heat loss and gain reports alongside ventilation checklists required by
the City of Vancouver, facilitating smooth permitting and compliance while optimizing
energy efficiency in the urban setting.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/241-Renfrew-Street-Vancouver-
Baseboard-Layout_Page_1-518x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/241-Renfrew-Street-Vancouver-
Baseboard-Layout_Page_2-518x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/241-Renfrew-Street-Vancouver-
Baseboard-Layout_Page_3-518x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/241-Renfrew-Street-Vancouver-
Mechanical-Drawing_Page_1-566x400.jpg)

 [  Alaskan Mechanical Design | Delta Junction, Alaska ](https://zencoredynamics.ca/home/projects/#accordion-item-alaskan-mechanical-design-|-delta-junction,-alaska)

For this off-grid residence in the remote expanses of Delta Junction, Alaska, we
engineered a robust mechanical design centered on a wood-fired boiler for primary
heating, seamlessly integrated with an electric backup boiler dedicated to domestic
hot water production. This hybrid system ensures reliable hot water availability
even during extreme cold snaps or low wood supply, optimizing self-sufficiency while
minimizing reliance on external power sources in the harsh subarctic environment.
The setup promotes sustainable energy use through renewable wood fuel, with the 
electric component providing efficient, on-demand redundancy for uninterrupted comfort
in an isolated setting.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/Delta-Junction-2-565x400.
png)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/Delta-Junction-4-565x400.
png)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/Delta-Junction-3-565x400.
png)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/Delta-Junction-531x400.
png)

 [  SANCO CO2 - Mechanical Design | Vancouver, CB ](https://zencoredynamics.ca/home/projects/#accordion-item-sanco-co2---mechanical-design-|-vancouver,-cb)

In this innovative design for a Vancouver residence, we specified the SANCO₂ heat
pump water heater system from ECO₂ Systems, a split air-to-water unit that utilizes
eco-friendly CO₂ refrigerant to extract heat from ambient air—even in temperatures
as low as -25°F or below—delivering hot water up to 150°F. This efficient setup 
integrates domestic hot water production with radiant in-floor heating, achieving
up to 80% energy savings over traditional electric resistance heaters and over 40%
compared to standard hybrid heat pumps, while minimizing environmental impact with
its low Global Warming Potential refrigerant.

The system features an outdoor heat pump connected via two water pipes to an indoor
insulated storage tank (available in sizes from 43 to 505 gallons), providing a 
high first-hour rating for abundant hot water and rapid recovery exceeding 20 gallons
per hour. For seamless operation, we incorporated custom controls design using Tekmar
532 Thermostats, a TACO ZVC406-5 Zone Control Valve, and Taco X Pump Block to manage
zoning, temperature modulation, and priority switching between DHW and space heating
demands, ensuring balanced performance and user-friendly automation.

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/Main-Floor-3D-752x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/Top-floor-3D-752x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/Full-House-3D-752x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/10/Full-Radiant-Panel-3D-
752x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/SancoCO2-4-618x400.png)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/SancoCO2-5-618x400.png)

![Mechanical design schematic for SANCO2 CO2 air-to-water heat pump system in Vancouver
BC, integrating domestic hot water, radiant in-floor heating, Tekmar 532 thermostats,
TACO zone valve, and pump block.](https://zencoredynamics.ca/wp-content/uploads/
2025/11/SancoCO2-2-518x400.png)

SANCO2 CO2 Air-to-Water Heat Pump System Design with Domestic Hot Water and Controls

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/SancoCO2-3-618x400.png)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/SancoCO2-618x400.png)

# Service and Maintenance

We provide expert service and maintenance for a wide range of mechanical and PLC
systems across diverse industries, including mining, data centers, and commercial
manufacturing—ensuring reliability, efficiency, and minimal downtime. For more videos
and stories showcasing our hands-on solutions, visit our YouTube channel or Instagram
profile.

 [  Proximity Sensor Repair | Delta, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-proximity-sensor-repair-|-delta,-bc)

At a bustling metal manufacturing facility in Delta, we were dispatched for urgent
service on an automated machine plagued by a failed proximity sensor and substandard,
unreliable splices in the wiring between the controller and equipment. These issues
caused intermittent downtime, halting production lines and risking safety protocols.
Our team swiftly diagnosed the faults, replaced the faulty sensor with a durable,
high-precision model suited for industrial environments, and rewired the connections
using secure, code-compliant terminations to eliminate shorts and ensure stable 
signal transmission. This quick intervention restored full operational efficiency,
minimizing losses and preventing future disruptions in the high-demand manufacturing
setting.

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20231204_085417-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20231204_085422-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20231204_085428-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20231204_141506-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20231204_142850-300x400.
jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/20231204_142905-300x400.
jpg)

# Legacy Projects: Major Achievements

Before diving into these landmark projects, a note: This section highlights significant
achievements from my time owning and leading a previous mechanical contracting firm.
While under a different banner, these endeavors laid the groundwork for the expertise
and innovation we bring to Zencore Dynamics today—showcasing large-scale executions
in HVAC, controls, and custom systems that continue to inform our approach.

 [  Arctic Fire Assay Installation | Hope Bay, Nunavut ](https://zencoredynamics.ca/home/projects/#accordion-item-arctic-fire-assay-installation-|-hope-bay,-nunavut)

Over an eight-month deployment in the remote gold mining operations of Hope Bay,
Nunavut—deep within the Arctic Circle—we engineered and installed comprehensive 
mechanical systems for a state-of-the-art fire assay assembly lab constructed from
eight 40-foot shipping containers. This critical facility processes rock samples
through crushing, melting, and spectral analysis to determine mineral content, supporting
efficient ore evaluation in extreme conditions. Facing relentless challenges like-
40°C temperatures, Blizzards, round-the-clock darkness during polar nights, and 
complex logistics reliant on cargo planes landing on frozen runways, our team delivered
resilient HVAC, ventilation, and piping solutions designed for subzero reliability.
This project honed our expertise in remote, high-stakes installations, ensuring 
uninterrupted lab functionality amid the Arctic’s unforgiving environment.

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3034-533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3036-533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3041-533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3065-533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3197-533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3201-533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3202-533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3275-300x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3276-300x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3277-300x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3280-300x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_3282-533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_2894-300x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_2931-533x400.jpg)

![](https://zencoredynamics.ca/wp-content/uploads/2025/11/IMG_2953-533x400.jpg)

 [  Holiday Inn Hotel | Terrace, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-holiday-inn-hotel-|-terrace,-bc)

For the Holiday Inn in Terrace, we handled the complete mechanical installation 
to support efficient operations and guest comfort across the multi-story facility.
This included deploying 93 PTAC (Packaged Terminal Air Conditioner) units for individualized
room climate control, a 10-ton air handler paired with a condenser for centralized
HVAC distribution, Engineered Air Make Up Air Unit,  a specialized pool dehumidifier
to maintain optimal humidity levels in the indoor aquatic area, and comprehensive
exhaust and ventilation systems to ensure fresh air circulation and code compliance.
Designed for Terrace’s northern climate with variable temperatures, this integrated
setup enhances energy efficiency, reduces maintenance needs, and provides reliable
performance for year-round hospitality demands.

 [  Comfort Inn Hotel | Terrace, BC ](https://zencoredynamics.ca/home/projects/#accordion-item-comfort-inn-hotel-|-terrace,-bc)

For the 92-room Comfort Inn, we managed the end-to-end mechanical installation to
deliver reliable guest comfort and operational efficiency in a demanding hospitality
environment. Key components included Engineered Air make-up units integrated with
a 10-ton AC system for fresh air intake and climate balancing, multiple 2- to 3-
ton forced air heat pumps paired with gas furnaces for zoned heating and cooling
across common areas, PTAC units for individual room control, and comprehensive building
exhaust and ventilation systems to maintain indoor air quality and comply with codes.
This robust setup optimizes energy use, supports variable occupancy loads, and ensures
year-round performance in British Columbia’s diverse weather patterns.